Reinforcement of existing structures
Deteriorated glue laminated tudor arch amputation
Failed tension member (Bottom Chord) - Modified bow string truss
Structural shoring services
Epoxy injection and re-lamination
Field Inspection Services
Furnish & install glue laminated structures


 

Project: Hofstra University

 

 
 
Picture 7- Hofstra University- Hempstead , NY
- Deterioration caused by water rot and carpenter ants is removed from compromised beam.

 
   
 
Picture 8- Hofstra University- Hempstead , NY
- Existing beam is prepared for new laminations by staggering the joints.

 
   
 
Picture 9- Hofstra University- Hempstead , NY
- New laminating stock southern yellow pine laminations are installed.

 
   
 
Picture10- Hofstra University- Hempstead , NY
- All exterior lamination surfaces are sealed with epoxy gel, ports are strategically placed and the beam is epoxy injected.

 
   
 
Picture 11- Hofstra University- Hempstead , NY
- Repaired beam is clad with aluminum for protection against further decay.
 

top


 
     

 

 

     